GEO SAVER D
1 August 2019Li-SOCI2 New Generation Disposable Battery
1 August 2019GEO SAVER P
The handy PRO GEOLOCALISED AED
AED per default can be easily switched in a Manual Defibrillator giving to ALS responders the best decision-making control for a manual shock timing or an electric cardioversion (synchronised shock). The 5.7″ full colour display enable to monitor the ECG and everything needed to know about the patient and ongoing rescue treatment in compliance with IEC/EN 60601-2-27.
ECG can also be sent in real time to the AMISAVERCLOUD PLATFORM to enable another operator to monitor the ECG simultaneously with the local rescuer.
most detailed and comprehensive screen provides valuable information to rescuers:
ABOUT DEVICE:
a battery gauge with residual capacity
the indicator of available memory for recording a notice if the microphone is active or OFF the local date and time, alarms.
ABOUT RESCUE:
the adult or child protocol in use
the modality in use (AED, ECG or Manual)
the fibrillation and shock counts:
the elapsed rescue time
the heart rate (bpm)
the impedance (ohms)
the energy level to be delivered (joule)
a touch/not touch pictogram
the ECG waveform the R wave detection in Manual Synchronous
a charging bar graph if device charges a CPR bar graph and cycles countdown
MODEL NUMBERS | |
Code SGP-B0994: | Standard Version maximum energy at 200J |
Code SGP-B0995: | Power Version with maximum energy at 360J |
CONFIGURATION OPTIONS (BOX CONTENT) | |
Conf-Norm: Standard Basic Configuration | (adult pads, disposable battery, carrying case) |
Conf-Rech: Rechargeable Configuration | (adult pads, accumulator, charger station, carrying case) |
Conf-Print: Print Ready Configuration | (adult pads, disposable battery, carrying case, IrDa port and thermal printer) |
Conf-Rech/Print: Rechargeable & Print Ready Configuration | (adult pads, accumulator, charger station, carrying case, IrDA port and thermal printer) |
Technical specifications
DEFIBRILLATOR | |
Operation: | AED Semi-Automatic (default) ECG Monitoring Manual Asynchronous or Synchronous (used to convert atrial or ventricular tachyarrthythimias) |
Energies: | Standard max 200J or Power max 360J |
Waveform: | Adaptive BTE (biphasic truncated exponential) conforming to patient chest’s impedance |
Energy Type: | Escalating from 50 to 360J |
AED Protocols: | Adult Standard escalating 150, 200, 200J Adult Power escalating 200, 250, 360J Pediatric (Standard or Power) 50J fixed (AED adult shock protocols can be customized) |
Manual Protocol: | Selected by users from 50 to 360J. For electric cardioversion (in Synchronous mode) the shock is synchronised to occur with the R wave of the ECG |
Energy Display: | Screen provides the energy to deliver both in Manual mode or AED mode |
Charging time: | ≤9 seconds with a new and fully charged battery depleted battery will result in a longer charging time |
Analysis time: | IEC/EN 60601-2-4 from 4 to 15 seconds |
Impedance: | 20-200 ohms |
Sensitivity: | IEC/EN 60601-2-4 (AHADB, MITDB source), 97% |
Specificity: | IEC/EN 60601-2-4 (AHADB, MITDB source), 99% |
Controls: | 2 buttons: ON/OFF, shock button, and 3 buttons to surf the menu. |
Indicators: | Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms |
Upgradeable: | through a USB cable or memory card or by remote through AMISAVERCLOUD |
ECG MONITORING |
|
Operations: | Through defibrillation pads or standard ECG electrodes attached to a separate 2-Lead patient monitoring reusable cable SAV-C0017 |
ECG size: | Manual setting through the menu |
Heart Rate: | 30-200 bpm |
Sweep Speed: | 25 mm/sec |
Standards: | IEC/EN 60601-2-27 less then the points 202.6.2.101; 201.12.1.101.12,13; 208.6.6.2.101 not performed for the intended use of the device, as it is not intended for environments such as operating theatres or intensive care units |
Display: | 5,7” TFT colour, 640 x 480 pixel |
BATTERY OPTIONS | |
Type: | Li-SOCl2 Disposable, code SAV-C1032 |
Autonomy: | 250 complete rescue cycles (shocks at 200J and CPR) or 160 complete rescue cycles (shocks at 360J and CPR) or 24 hours ECG analysis for a new and fully charged battery (*) |
Shelf-Life: | when stored in original packaging 5 years (*) |
Battery-Life: | 4 years once installed to AED, assuming one battery insertion test and daily self-test but without switching AED on (*) |
Type: | Li-ion Accumulator, code SAV-C1033 |
Recharging time: | 2,5 hours with the charger station code SAV-C1034 (*) (recommended to charge every 4 months at least) |
Autonomy: | 200 shocks at 200J or 110 shocks at 360J or 14 hours in ECG Monitoring for a new fully charged accumulator (*) |
Battery-Life: | 2 years or 300 charging cycles (*) |
PADS OPTIONS | |
Type: | Disposable, pre-gelled and self-adhesive |
Adult: | Code SAV-C0846, for patient >8 years or >25 kg |
Pediatric: | Code SAV-C0016, for patient <8 years or <25 kg |
Cable length: | 120 cm |
Shelf-Life: | 30 months |
EVENT RECORDING | |
Internal memory: | up to 6 continuous hours of ECG and rescue events |
Optional memory: | Removable SD card; length of storage depends on card capacity: a 2GB card records up to 100 hours |
Data recording: | “AED1LOG“ text file with detailed self-test activity “AEDFILES“ multimedia files with complete recorded information |
Event review: | “Saver View Express“ data manager software |
PHYSICAL | |
Size: | 29,5 x 23 x 11,5 cm |
Weight | +/- 2,85 Kg |
ENVIROMENTAL | |
Operating temperature: | 0°C to 55°C (32°F TO 131°F) |
Storing/Shipping temperature: | -40°C to 70°C (-40°F TO 158°F) without battery |
Humidity: | 10% to 95% relative humidity non condensing |
Sealing (IP Protection): | IEC/EN 60529 class IP56; splash proof, dust protected |
Shock/Drop Abuse Endurance: | IEC/EN 60601-1 clause 21; 1 meter drop, impact, force, rough handling, mobile tolerance |
Electrostatic Discharge: | IEC/EN 61000-4-2 |
Electromagnetic Compatibility: | IEC/EN 60601-1-2 Emission, Immunity |
Electrical Protection: | IEC/EN 60601-1; Internally Powered, Type BF/CF |
Directive93/42/CEE and 2007/47/CE: | Class IIb |
GEOLOC MODULE | |
Frequency: | GSM: 850, 900, 1800, 1900 MHz; UMTS: 900, 2100 MHz GPS: 1575, 1600 MHz |
GEOLOC BATTERY OPTIONS | |
Type: | Li-SOCl2 Disposable, code SAV-C1038 |
Shelf-Life: | when stored in original packaging 5 years (*) |
Battery-Life: | 4 years once installed to AED, assuming one battery insertion test and daily self-test but without switching AED on (*) |
Type: | Li-ion Accumulator, code SAV-C1039 |
Recharging time: | 2,5 hours with the charger station code SAV-C1040 (*) (recommended to charge every 4 months at least) |
Battery-Life: | 2 years or 300 charging cycles (*) |
(*)Temperature at 20°C Humidity 45% non-condensing |